C++ Library 73
Mode:
EOC or Half-full interrupt transfer mode selection
0: EOC interrupt transfer mode
1: Half-full interrupt transfer mode
@ Return Code
ERR_NoError
ERR_BoardNoInit,
ERR_InvalidADChannel,
ERR_InvalidTimerValue
ERR_AD_InvalidGain
6.10.2 _9116_AD_INT_Status
@ Description
Since the _9116_AD_INT_Start() function runs in the background, this
function can be used to check its operation status.
@ Syntax
C/C++ (DOS)
int I16 _9116_AD_INT_Status( I16 card_number, I16 *status , U32
*count);
@ Argument
card_number:
the card number of the cPCI-9116 to be initialized,
totally 4 cards can be initialized, valid card
numbers are CARD_1, CARD_2, CARD_3,
CARD_4.
Status:
status of the DMA data transfer
AD_INT_STOP (or 0)
: Interrupt transfer is
completed.
AD_INT_RUN (or 1)
: Interrupt transfer is not
completed.
Count:
the number of A/D data that has been transferred.
@ Return Code
ERR_NoError
ERR_AD_DMANotSet
ERR_BoardNoInit