Installation
The internal voltage can be set to -5V or -10V which is selected by JP1 for
the ACL-8112DG/HG and JP8 for the ACL-8112PG. Possible configurations
are specified in Figure 2.9. Note that the internal reference voltage is used
only when JP2 of the ACL-8112DG/HG or JP6 and JP7 of the ACL-8112PG
is set to internal reference.
Reference Voltage is
-5V (default setting)
JP1 /
JP8
-10V
-5V
Reference Voltage is
-10V
JP1 /
JP8
-10V
-5V
Figure 2.9 Internal Reference Voltage Setting
2.12 A/D Input Range Setting
(This section is for the ACL-8112PG only)
The A/D input range of the ACL-8112PG can be set to ±5V or ±10V using
JP9.
A
/D Input Range is +/-
5V (default setting)
JP9
10
5
JP9
10
5
A
/D Input Range is +/-
10V
Przeglądanie stron 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 93 94

Komentarze do niniejszej Instrukcji

Brak uwag

Mundoclima MUP-09 CE manuals

Owner’s manuals and user’s guides for Split-system air conditioners Mundoclima MUP-09 CE.
We providing 1 pdf manuals Mundoclima MUP-09 CE for download free by document types: User Manual






More products and manuals for Split-system air conditioners Mundoclima

Models Document Type
ALL IN ONE Type Air-source Heat Pump Water Heater Service Manual   mundoclima ALL IN ONE Type Air-source Heat Pump Water Heater Service manual, 33 pages
MUP-24 CE User Manual   Manual de usuario e instalación Mundoclima Serie MUP 12x2HG [en] , 24 pages
MUCR 24 HF Installation Manual    mundoclima MUCR 24 HF Installation manual [en] , 34 pages
ALL IN ONE Type Air-source Heat Pump Water Heater User Manual   mundoclima ALL IN ONE Type Air-source Heat Pump Water Heater User`s manual, 35 pages
MUP-24 CE User Manual    Manuel de l`Usager - Salvador Escoda SA, 35 pages