Operation Theory
I/O Address
The 8254 in the ACL-8112 occupies 4 I/O address as shown below.
BASE + 0 LSB OR MSB OF COUNTER 0
BASE + 1 LSB OR MSB OF COUNTER 1
BASE + 2 LSB OR MSB OF COUNTER 2
BASE + 3 CONTROL BYTE
The programming of the 8254 is control by registers BASE+0 to BASE+3.
The function of each register is specified in this section. For more detailed
information, refer to the 8254 handbook.
Control Byte
Before loading or reading any of these individual counters, the control byte
(BASE+3) must be loaded first. The format of the control byte is:
Bit 7 6 5 4 3 2 1 0
SC1 SC0 RL1 RL0 M2 M1 M0 BCD
SC1 & SC0 - Select Counter ( Bit7 & Bit 6)
SC1 SC0 COUNTER
0 0 Select Counter 0
0 1 Select Counter 1
1 0 Select Counter 2
1 1 ILLEGAL
RL1 & RL0 - Select Read/Load operation ( Bit 5 & Bit 4)
RL1 RL0 OPERATION
0 0 COUNTER LATCH FOR STABLE READ
0 1 READ/LOAD LSB ONLY
1 0 READ/LOAD MSB ONLY
1 1 READ/LOAD LSB FIRST, THEN MSB
M2, M1 & M0 - Select Operating Mode ( Bit 3, Bit 2, & Bit 1)
M2 M1 M0 MODE
0 0 0 0
0 0 1 1
x 1 0 2
x 1 1 3
1 0 0 4
1 0 1 5
BCD - Select Binary/BCD Counting ( Bit 0)